  wall industries, inc. 5 watson brook road exeter, nh 03833 09/20/2012 603-778-2300 www.wallindustries.com fax 603-778-9797 page 1 of 5 datasheet rev. a dtmpu31 series 90~264vac input voltage range class i, up to 30 watts single, dual, and triple outputs 3 rd edition medical approvals medical ac/dc desktop power supplies features ? class i ? rohs compliant ? ul 94v-1 compliant ? energy star 2.0, efficiency level v ? iec-320-c14 ac inlet connector ? 100% burn-in tested ? single, dual, and triple outputs ? up to 30 watts output power ? wide input voltage range: 90~264vac ? over voltage and over load protection ? meets fcc part-18 class b and cispr-11 en55011 class b emission limits ? ansi/aami es 60601-1:2005 (ul/cul 3 rd edition) and en 60601-1:2006 (tuv/t-mark 3 rd edition) safety approvals ? input to output: 2mopp ? optional output connectors available description the dtmpu31 series of class i medical ac/dc desktop power s upplies provides up to 30 watts of continuous output power in a 4.65? x 2.56? x 1.52? package. this series consists of single, dual, and triple output models with a 90~264vac input voltage range and an iec-320-c14 ac inlet connector. these power supplies are protected against over voltage and over load conditions and have been 100% burn-in tested. all units are ul 94v-1 and rohs compliant and meet fcc part-18 class b and cispr-11 en55011 class b emission limits. the dtmp u31 series also meets new ce requirements and has ansi/aami es 60601-1:2005 (ul/cul 3 rd edition) and en 60601-1:2006 (tuv/t-mark 3 rd edition) safety approvals. medical
rev. a dtmpu31 series class i, up to 30 watts single, dual, & triple outputs medical ac/dc desktop power supplies wall industries, inc. 5 watson brook road exeter, nh 03833 09/20/2012 603-778-2300 www.wallindustries.com fax 603-778-9797 page 2 of 5 specifications: dtmpu31 series all specifications are based on 25c, nominal input volt age, and maximum output current unless otherwise noted. we reserve the right to change specifi cations based on technological advances. specification test conditions min nom max unit input specifications operating input voltage range 90 264 operating voltage range safety approvals input voltage range 100 240 vac input frequency 47 63 hz io = full load, vin = 100vac 0.9 input current io = full load, vin = 240vac 0.34 a io = full load, 25c, cold start, vin = 115vac 14 inrush current io = full load, 25c, cold start, vin = 230vac 28 a single output models 0.3 no load power consumption no load, vin = 230vac dual & triple output models 3 w output specifications output voltage see table line regulation io = full load 1 % load regulation vin = 230vac 2 10 % output power vin = 90 to 264vac see table output current see table outputs under 3.3vdc 2 ripple & noise (peak to peak) full load, vin = 90vac others 1 % transient response time io = full load to half load, vin = 100vac 4 ms hold-up time io = full load, vin = 110vac 12 ms start-up time io = full load, vin = 100vac 0.3 2 s temperature coefficient -0.04 +0.04 %/c protection over voltage protection 112 132 % over current protection 110 150 % general specifications efficiency io = full load, vin = 230vac 67.6 85 % primary to secondary 6802 dielectric withstanding voltage primary to pe 2121 vdc isolation resistance test voltage = 500vdc 50 m ? safety ground leakage current vin = 240vac/60hz 0.1 ma environmental specifications operating temperature derating linearly from 100% load at 50c to 50% load at 70c 0 40 70 c storage temperature -40 85 c operating humidity 0 95 % storage humidity 0 95 % operating altitude up to 3000m mtbf operating temp. at 25c; calculated per mil-hdbk-217f 100,000 hours physical specifications weight approx. 14.1~16.2oz (400~460g) dimensions (l x w x h) 4.65 x 2.56 x 1.52 inches (118.0 x 65.0 x 38.5 mm) ac inlet connector iec-320-c14 safety & compliance safety approvals ansi/aami es 60601-1: 2005 (ul/cul 3 rd ed.), en 60601-1:2006 (tuv/t-mark 3 rd ed.), ce emi requirements fcc part-18 class b and cispr-11 en55011 class b compliance rohs, ul 94v-1, cec/energy star 2.0, efficiency level v
rev. a dtmpu31 series class i, up to 30 watts single, dual, & triple outputs medical ac/dc desktop power supplies wall industries, inc. 5 watson brook road exeter, nh 03833 09/20/2012 603-778-2300 www.wallindustries.com fax 603-778-9797 page 3 of 5 model selection table single output models model number input voltage range output voltage (1) max. output current total regulation max. output power dtmpu31-101 90~264 vac 3 ~ 5 vdc 6.66 ~ 4.00a 7% 20w dtmpu31-102 90~264 vac 5 ~ 6 vdc 5.00 ~ 4.16a 5% 25w dtmpu31-103 90~264 vac 6 ~ 8 vdc 4.16 ~ 3.12a 5% 25w dtmpu31-104 90~264 vac 8 ~ 11 vdc 3.75 ~ 2.72a 4% 30w dtmpu31-105 90~264 vac 11 ~ 13 vdc 2.72 ~ 2.30a 3% 30w dtmpu31-106 90~264 vac 13 ~ 16 vdc 2.30 ~ 1.87a 3% 30w DTMPU31-107 90~264 vac 16 ~ 21 vdc 1.87 ~ 1.42a 3% 30w dtmpu31-108 90~264 vac 21 ~ 27 vdc 1.42 ~ 1.11a 2% 30w dtmpu31-109 90~264 vac 27 ~ 33 vdc 1.11 ~ 0.90a 2% 30w dtmpu31-110 90~264 vac 33 ~ 40 vdc 0.90 ~ 0.75a 2% 30w dual output models output current model number input voltage range output voltage min max. max. regulation max. output power vo 1 +3.3 vdc 0.30a 3.0a 7% dtmpu31-200 vo 2 90~264 vac +12 vdc 0.13a 1.3a 5% 25w vo 1 +5 vdc 0.30a 3.0a 5% dtmpu31-201 vo 2 90~264 vac +12 vdc 0.13a 1.3a 5% 30w vo 1 +5 vdc 0.30a 3.0a 5% dtmpu31-202 vo 2 90~264 vac +15 vdc 0.10a 1.0a 5% 30w vo 1 +5 vdc 0.30a 3.0a 5% dtmpu31-203 vo 2 90~264 vac +24 vdc 0.07a 0.7a 5% 30w vo 1 +3.3 vdc 0.30a 3.0a 7% dtmpu31-204 vo 2 90~264 vac +5 vdc 0.16a 1.6a 5% 17.9w vo 1 +12 vdc 0.20a 2.0a 5% dtmpu31-209 vo 2 90~264 vac -12 vdc 0.05a 0.5a 10% 30w vo 1 +15 vdc 0.15a 1.5a 5% dtmpu31-210 vo 2 90~264 vac -15 vdc 0.05a 0.5a 10% 30w vo 1 +5 vdc 0.30a 3.0a 5% dtmpu31-215 vo 2 90~264 vac -24 vdc 0.10a 1.0a 10% 30w triple output models output current model number input voltage range output voltage min max. max. regulation max. output power vo 1 +5 vdc 0.25a 2.5a 5% vo 2 +12 vdc 0.11a 1.1a 5% dtmpu31-301 vo 3 90~264 vac -5 vdc 0.05a 0.5a 10% 25w vo 1 +5 vdc 0.25a 2.5a 5% vo 2 +12 vdc 0.10a 1.0a 5% dtmpu31-302 vo 3 90~264 vac -12 vdc 0.05a 0.5a 10% 30w vo 1 +5 vdc 0.25a 2.5a 5% vo 2 +15 vdc 0.10a 1.0a 5% dtmpu31-303 vo 3 90~264 vac -15 vdc 0.05a 0.5a 10% 30w vo 1 +5 vdc 0.30a 3.0a 5% vo 2 +24 vdc 0.10a 1.0a 5% dtmpu31-304 vo 3 90~264 vac -24 vdc 0.05a 0.5a 10% 30w vo 1 +5 vdc 0.30a 3.0a 5% vo 2 +24 vdc 0.10a 1.0a 5% dtmpu31-305 vo 3 90~264 vac -12 vdc 0.05a 0.5a 10% 30w vo 1 +3.3 vdc 0.30a 3.0a 5% vo 2 +12 vdc 0.11a 1.1a 5% dtmpu31-306 vo 3 90~264 vac -5 vdc 0.05a 0.5a 10% 25w notes 1. for single output models the output voltage is specified as a range (ex: 33~40vdc); the customer must specify what they woul d like the output voltage set at. 2. models dtmpu31-101~104 need to use awg#16/4ft output cable in order to meet the total regulation specified. models dtmpu31-105~108 need to use awg#18/6ft out put cable in order to meet the total regulation specified. models dtmpu31-109~110 need to use awg#20/6ft output cab le in order to meet the total regulation specified. the regulation and efficiency will ch ange if a different output cable is used. 3. optional output connectors available. please call factory for ordering details.
rev. a dtmpu31 series class i, up to 30 watts single, dual, & triple outputs medical ac/dc desktop power supplies wall industries, inc. 5 watson brook road exeter, nh 03833 09/20/2012 603-778-2300 www.wallindustries.com fax 603-778-9797 page 4 of 5 derating curve ambient temperature (c) output power (%) 0 10 20 30 40 50 60 70 80 120 100 80 60 40 20 0 mechanical drawing unit: inches (mm) led 2.560.04 (65.01.0) 4.650.04 (118.01.0) 0.040.02 (1.00.5) 0.060.02 (1.50.5) 1.520.04 (38.51.0) ac inlet iec-320-c14 switching power notes 1. weight: 14.1~16.2oz (400~460g) 2. ac inlet: iec-320-c14 3. models dtmpu31-101~104 need to use awg#16/4ft output cable. models dtmpu31-105~108 need to use awg#18/6ft output cable. models dtmpu31-109~110 need to use awg#20/6ft output cable. the regulation and efficiency will change if a different output cable is used. 4. optional output connectors available.
rev. a dtmpu31 series class i, up to 30 watts single, dual, & triple outputs medical ac/dc desktop power supplies wall industries, inc. 5 watson brook road exeter, nh 03833 09/20/2012 603-778-2300 www.wallindustries.com fax 603-778-9797 page 5 of 5 company information wall industries, inc. has created custom and modified units for over 50 years. our in-house research and development engineers will provide a solution that exceeds your perfo rmance requirements on-time and on budget. our iso9001-2008 certification is just one example of our commitment to produc ing a high quality, well-documented product for our customers. our past projects demonstrate our commitment to you, our cu stomer. wall industries, inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and f unction requirements. we will continue to provide ongoing support for your project a bove and beyond the design and production phases. give us a call today to discuss your future projects. contact wall industries for further information: phone : ? (603)778-2300 toll free : ? (888)587-9255 fax : ? (603)778-9797 e-mail : sales@wallindustries.com web : www.wallindustries.com address : 5 watson brook rd. exeter, nh 03833


▲Up To Search▲   

 
Price & Availability of DTMPU31-107

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X